Showing posts with label environmental analysis. Show all posts
Showing posts with label environmental analysis. Show all posts

Friday, October 10, 2014

A New Method for ppb Analysis of H2S in Air and Water

Accepted for presentation at Pittcon 2015
March 8 - 12, 2015
New Orleans, LA
Abstract Number: 770 - 3
Session 770 - Environmental - LC/GC Techniques
Day and Time: Monday, March 09, 2015, 02:10 PMRoom 257
Authors: Jack Driscoll and Jennifer Maclachlan, PID Analyzers, LLC




Methodology:Gas ChromatographyApplication: EnvironmentalPrimary Focus: ApplicationTitle: A New Method for ppb Analysis of H2S in Air and WaterKeywords:
Environmental Analysis
Gas Chromatography
GC Detectors
Specialty Gas Analysis

The photoionization detector (PID) is a very sensitive GC detector for sulfur compounds with pg detection limits for hydrogen sulfide. This compound can be efficiently collected in the field in an impinger with a basic solution (0.01M NaOH) at a known period of time and flow rate. The solution should be kept out of sunlight. Back in the lab, since the pKa for H2S is 6.9, the addition of 0.1 M acid will convert the sulfide (collected) to H2S which can be swept out of a vessel with an inlet, exhaust and septum (for addition of acid {H+}). Once the H+ is added, the solution is stirred for several minutes, then the nitrogen is turned on at 15 cc/min/ and the H2S is swept into the sample loop of the six port GC injection valve. The H2S is separated on a porous polymer column and detected by the PID. A 10ng/L sample (permeation tube) of H2S collected for 10 minutes indicated a detection limit (3 sigma) of 0.9 ppb. The coefficient of variation at 25 ppb was 16.3% for 5 successive runs. The PID has a dynamic range > 107 so a high level stack sample (200 ppm) would still be in the linear range with a slightly shorter sampling time.


Here's the full session lineup: 

Friday, March 2, 2012

Analysis of Volatile and Semivolatile VOC’s in Waste Oils

Scroll down for FULL presentation
Methodology:Gas Chromatography
Application:Environmental
Primary Focus:Methodology
Title:Analysis of Volatile and Semivolatile VOC’s in Waste Oils
Keywords:
Detector
Environmental Analysis
Gas Chromatography
Headspace
 
Assignment Status:Assigned CO-669Session Title:New Developments in Analytical Instrumentation and Software
Session Date03/11/2012Starting Time:( Slot # 16 )

PID Analyzers, LLC Model 322
 Author: Jack Driscoll, PID Analyzers, LLC

EPA Method 8021B  describes methods for analysis of volatile aromatics in solid wastes by gas chromatography (GC) with a photoionization detector (PID). This method is  designed for analysis of solid wastes and will have to be modified for waste oil analysis. EPA describes   headspace, purge and trap, direct injection and vacuum distillation methods. The latter three methods are more suited to solids than oils. In addition, the purge and trap method requires a considerable amount of equipment. Our application is for a small number of daily samples. The headspace method is ideal for oils but will require some modifications for oils.

EPA Method 8082A for the analysis of polychlorinated bi phenyls (PCB’s) involves solvent extraction  of solid, tissue or aqueous samples and detection by GC with an electron capture  detector or electrolytic conductivity detector. We will modify this method by using a PID for detecting the PCB’s and selecting an extraction  solvent that will not be miscible with the oil.  For each of the methods, we will determine the precision, accuracy and recovery efficiency from a variety of oils.
Two methods were developed using the same column but with different techniques. 
The volatiles required 15 minutes of heating in a VOC vial before analysis. The analysis time was 3 minutes. The precision was +/- 5%.
The SVOC sample was diluted 1:1 with hexane and injected. We could recognize the difference between various PCB's using the PID. The precision of the method was +/- 11% 25 ppm.

Determination of Volatiles and PCB's in Transformer Oil Final (1)

Wednesday, November 9, 2011

New brochure: #FID for process, stack, QC, env measurements #flameionization

Flameionization analyzers from PID Analyzers  




 When the job calls for an FID, we've got the right one for you: Our new brochure below describes our family of analyzers "FID for all occasions" featuring applications including process, stack gas measurement, environmental analysis and QC batch analysis.
FID for All Occasions 4p 1011

Wielding social media for effective science communication

  ABSTRACT SYMPOSIUM NAME: Combatting Science Mis- and Dis-Information ABSTRACT SYMPOSIUM PROGRAM AREA NAME:  CINF CONTROL ID:  3910009 PRES...