Analysis of Greenhouse Gases in Ambient Air by GC/FUV accepted for presentation at #Pittcon


On January 1, 2010, the U.S. Environmental Protection Agency required large emitters of heat-trapping emissions to begin collecting greenhouse gas data under a new reporting system. Nitrous oxide (N2O) Carbon dioxide (CO2), methane (CH4) and are considered the main greenhouse gases in the Earth's atmosphere. These gases absorb strongly in the infrared trapping heat in the atmosphere and affecting the temperature on the Earth. These gases have been measured using expensive long path infrared analyzers or complex gas chromatography using as many as three detectors and three valves. We developed a far UV absorbance detector (FUV 1) that we will apply to analysis of all three gases. It will just require a concentrator to detect ppb levels of these gases. The FUV detector recently has been improved so that it can detect low ppm levels of these compounds. We had developed a concentrator for N2O that could also be used for CO2 and plan some additional changes to the FUV to improve its sensitivity to CH4. 


1. Driscoll, JN "UV Ionization Detectors in High Resolution Chromatography", Capillary Chromatography, Hill, H. ed., Wiley & Sons, NY (1992)

2. Environmental Protection Agency (EPA), “40 CFR Parts 86, 87, 89 et al. Mandatory Reporting of Greenhouse Gases; Final Rule“.


Abstract Number: 1030 - 66
Session 1030 - Environmental Posters
Day and Time: Tuesday, February 27, 2018, Afternoon
Room Exposition Floor, Aisles 2000-2700



Tuesday, October 24, 2017

A Portable GC/PID for the Analysis of Odorous Sulfur Compounds in Ambient Air











Methodology:
Feb 26 - Mar 1, 2018
Orange County Convention Center
Orlando, FL, USA

Accepted for presentation at #Pittcon 2018 in the American Chemical Society Division of Analytical Chemistry Poster Session

Sunday evening February 25, 2018 Valencia Ballroom D, W415, of the Orange County Convention Center, 5:30pm-7:30pm

Gas Chromatography
Application:Environmental
Primary Focus:Application
Title:A Portable GC/PID for the Analysis of Odorous Sulfur Compounds in Ambient Air
Keywords:
Air
GC
Industrial Hygiene
Portable Instruments
 

A capillary column gas chromatography method was used for the analysis of sulfur compounds such as hydrogen sulfide, methyl mercaptan, dimethyl sulfide, and dimethyl disulfide in ambient air. The concentration of these sulfur compounds is typically very low (low to sub ppb) in ambient air. Their odor threshold is at the low ppb levels so it is also necessary to make field measurements near odorous sulfur sources such as refineries, pulp and paper mills, etc. because of the high reactivity of the sulfur compounds. A portable gas chromatograph (GC) with a photoionization detector (PID) and concentrator is ideal for this application because of the high sensitivity of the PID to sulfur


compounds and it does not need support gases such as zero air or hydrogen. It has more than 100 times the sensitivity of the flame photometric detector and a much wider dynamic range.

Wielding social media for effective science communication

  ABSTRACT SYMPOSIUM NAME: Combatting Science Mis- and Dis-Information ABSTRACT SYMPOSIUM PROGRAM AREA NAME:  CINF CONTROL ID:  3910009 PRES...